The Standard in Rugged Power Products

ETI0001-1458 2.0 kVA
   
Home Up All of these products are manufactured by ETI in the United States.

Up
ETI0001-1402 1.5 kVA
ETI0001-1403 1.5 kVA
ETI0001-1406 3.0 kVA
ETI0001-1417 1.5 kVA
ETI0001-1419 2.0 kVA
ETI0001-1420, 1.0 kVA
ETI0001-1429 2.4 kVA
ETI0001-1437 2.0 kVA
ETI0001-1438 2.0 kVA
ETI0001-1439 4.0 kVA
ETI0001-1442 4.0 kVA
ETI0001-1443 2.0 kVA
ETI0001-1444 2.0 kVA
ETI0001-1445 2.0 kVA
ETI0001-1447 2.0 kVA
ETI0001-1450 2.0 kVA
ETI0001-1451 4.0 kVA
ETI0001-1451AA 4.0 kVA
ETI0001-1452 4.0 kVA
ETI0001-1452AA 4.0 kVA
ETI0001-1453 4.0 kVA
ETI0001-1455 4.0 kVA
ETI0001-1456 4.0 kVA
ETI0001-1458 2.0 kVA
ETI0001-1467 2.0 kVA
ETI0001-1473 2.0 kVA
ETI0001-1473AA 2.0 kVA
ETI0001-1473AF 2.0 kVA
ETI0001-1473A 2.0 kVA
ETI0001-1473B 2.0 kVA
ETI0001-1474 2.0 kVA
ETI0001-1479 1.0 kVA
ETI0001-1482 2.0 kVA
ETI0001-1483 2.0 kVA
ETI0001-1486 2.0 kVA

Part Number: ETI0001-1458 
MilSpec 2000VA Rugged Integrated
Rackmount UPS and Intelligent
Power Distribution Unit

Navy PowerStationÔ Mil Spec N5 Configuration
2000 VA Rugged Rack Mount Isolated UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
With Drip Proof Front Panel, Shallow Depth, Removable Battery

ETI0001-1458 2000VA Rugged UPS Front View
ETI0001-1458 Standard Front Panel Layout

ETI0001-1458 2000VA Rugged UPS Rear View
ETI0001-1458 Standard Rear Panel Layout

N5 Remote Control Panel can be mounted up at eye level or on the keyboard console or anywhere up to 50 feet away!

Standard Remote Control/Display Panel

 


Optional ETI0001-0876 UPS and PDU Remote Control Panel in 1U

The field proven PowerStation™ UPS line is ideally suited for military, industrial and telecommunications applications requiring a rugged rack, vehicular or field deployable, high reliability, compact size and light weight design. The heavy-duty chassis occupies only 4U (7.0”) of rack space and is only 18.5" deep making it suitable for shallow racks as found on submarines. The front panel is sealed meeting the Navy drip proof requirements. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The internal shielded input isolation transformer, EMI/RFI filters and input power factor correction minimize both input current and harmonics. The "1458" has the added benefit of having a field replaceable battery via a rear drawout battery module. The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front panel with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus battleshort override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console with only a logic level cable connection. Both the input circuit breaker and isolation transformer provide double pole isolation for shipboard systems.

The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are unique allowing the use of either standard NEMA 5-15P plugs or MS threaded metal shell connectors. The washable air filters and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The status D shell connectors provide signal interfaces with optional computer software and the remote display/control panels. 

Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N: ETI0001-1458

AC OUTPUT
Output voltage: 120 VAC true sinewave std, up to 600 VAC optional
Output rating: UPS 2000 VA in 4U chassis x 18.5" deep
0.65-0.75 pf std, optional configurations to 24,000 VA
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 2.5% synchronized to utility
60 Hz ± 1.0% w/ utility not available

50, 400 or 1000 Hz output available as an option
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: 120 VAC, optional up to 600 VAC, up to 440 Hz
Input voltage tolerance: UPS +15% -25% of nominal input rating
Input/output isolation: 2000 VA,>120 dB common mode,<1.5mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole input breaker w/ UPS fuse
Optional cold start to turn on w/o AC present
Input power connection: MS 3102A-22-2P, 3 pin, threaded locking
BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal DC protection: Front panel mounted fuse (F1)
Internal battery time: 10+ minutes @ 100% load, 25+ minutes @ 50%
Internal battery recharge: Recharged to nominal in 8 hours
Internal battery replacement: Drawout/plug-in module from front of unit
DISTRIBUTION PANEL
Output circuits: Six controlled outputs w/2 pole solidstate relays
Output control: Local/remote control panel w/rocker switches
Thermal and remote interlock ON/OFF control
Output receptacles: (6) MS / NEMA 5-15R threaded locking, various options
MECHANICAL
Dimensions ( H x D x W ): 7.0 (4U) x 18.5 x 19.0 in (178x470x483mm)
Rack Slide Mount Patterns: Jonathan or General Devices patterns
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 105 lb. (48 kg) UPS, 64 lb. (29 kg) Battery
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to sides
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C)
Operating temperature: 32° to 122° F ambient ( 0° to 50° C)
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 10,000 ft (3,048 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC, Class A, MIL STDs 461
OPTIONAL ACCESSORIES
  Dual Source Input, Batteryless Operation,
Battery Expansion Unit, Automatic Battery Test,
Software Interface

This page was last modified on: May 04, 2008
The N5 is one of the most popular configurations for new programs!

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Have an engineer contact me
Have a salesperson contact me
I prefer to be contacted by Email   Telephone  Fax  Regular mail
My requirement is immediate  1-3 months  3-6 months  Future

Name
Title
Company
Address
Email
Phone
Fax

To Better Help
You, Please
Describe Your
Requirements

The N5 is one of the most popular configurations for new programs!

Home Up

Send questions or comments about this web site to webmaster@ruggedsystems.com.
Copyright © 1991- 2008 Energy Technologies, Inc. All Rights Reserved. Last modified: October 11, 2008

1stEnergy™, 1stPower™, 24-7Backup™, 911power™, AC24-7™, ACanytime™, ACanywhere™, ACbackup™, ACintegrity™, AirborneBackup™, AirbornePower™, ArmyBackup™, BackupAC™, BackupSource™, BackupTheWeb™, BattlePower™, BlackoutPrevention™, BusinessBackUPS™, cleanUPS™, ControllingPower™, DC24-7™, DCbackup™, DCintegrity™, EcoPowerSource™, eDocsPort™, EnergyTech™, ETI™, ExtremePowerSource™, FuelCellUPS™, GlobalPowerSource™, GlobalUPS™, HomelandBackup™, HomelanSecurity24-7™, ImprovedPower™, IndustrialBackup™, InfoBackup™,  IntelligentUPS™, InternetPowerManager™, LabPower™, LabUPS™, LightUPS™, KnowPower™, MarineCorpBackup™, MarineCorpPower™, MedicalAC™, MedicalBackup™, MilitaryBackup™, NavigationPower™, NavyPower™, NetworkPowerManager™, NonStopAC™, OfficeUPS™, OnsiteBackup™, openUPS™, PersonalSource™, PetroChemPower™, PipelinePower™, PortablePowerPlant™, PoweringTheNet™, PowerProtection™, PowerSecurity™, PowerStatus™, PreventingBlackouts™, RedundantPower™, RenewableSource™,  RuggedPower™, RuggedSystems™, SCADApower™, SecurityGatePower™, ShipboardPower™, SignalBackup™, SolarBackup™, SolarPowerSource™, TacticalComputers™, TacticalComputerWorkstations™, TelecomBackup™, TelecomPowerSource™, ThePowerConnection™, TrafficBackup™, TrafficSignalBackup™, UPStart™, UtilityBackup™, windUPS™, WarfighterBackup™, WarfighterPower™, and WorldPower™ are trademarks of Energy Technologies, Inc.

Diplomatic Power®, Extreme UPS®, Industrial Power Source®, Military Power®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, TacticalPower®, Tactical Power Plant®, Tactical Solar® and Tactical UPS® are registered trademarks of Energy Technologies, Inc.

Legal Statements